DESCRIPTION:


Oil I.D. is a field test kit that quickly and easily identifies the type of refrigeration oil used in air conditioning and refrigeration systems. No longer does the service contractor have to guess what type of oil is being used in the system, nor have to wait days for an expensive laboratory analysis. This inexpensive product will tell you within seconds if the oil being used is a Polyol Ester (POE) oil or another type.

Oil I.D. helps avoid the costly mistake of mixing different oils. No refractometer or laboratory analysis required.
Top of Page

CHARACTERISTICS:


  • Quick, inexpensive method for identifying the type of refrigeration oil used in air conditioning and refrigeration systems
  • Saves time and money
  • Eliminates need for refractometer or expensive laboratory test
  • Avoid costly mistake of mixing POE and mineral refrigerant oils
  • Easy to use
  • Determines if oil is POE or another type
  • Top of Page

    APPLICATIONS:


    Top of Page

    PACKAGING:


    Code Qty. Per Case Lbs. per Case Cu. Ft Per Case
    45001

    12 boxes

    3 0.22

    Top of Page

    INSTRUCTIONS:


    1. Pour the refrigerant oil to be tested into the glass bottle containing Oil I.D.

    2. With the glass bottle capped, invert the bottle 10 times.

    3. Look for gelling to appear.

    4. If the oil is POE, gelling will appear within 30 seconds.

    5. If the oil is a mineral oil or an alkylbenzene, no gelling will appear.

    For additional technical information, call Toll Free 1-800-231-3345.

    Top of Page

    PRECAUTIONS:


    FOR CHEMICAL EMERGENCY, SPILL, LEAK, FIRE, EXPOSURE OR ACCIDENT,

    CALL CHEMTREC - DAY OR NIGHT 1-800-424-9300

    W A R N I N G!

    FLAMMABLE - POISON

    CONTAINS: Isopropyl alcohol. PRECAUTIONS: May cause eye and skin irritation. Harmful or fatal if swallowed. Keep away from heat, sparks, and flame. Wash thoroughly after use. FIRST AID: For any overexposure, get immediate medical attention after first aid is given. Eyes and Skin - Flush with large amounts of clean water for at least 15 minutes. Inhalation - Remove to fresh air. Ingestion - Only if conscious, give large amounts of water. DO NOT INDUCE VOMITING. FIRE AND SPILLS: For fire, use water fog, CO2, foam or dry chemicals to extinguish. For spills, shut off ignition sources, ventilate confined areas and wipe up with absorbent materials to prevent footing hazard. STORAGE AND HANDLING: Store in cool place away from all food. Keep container upright and tightly closed when not in use. Do not reuse empty container. KEEP OUT OF REACH OF CHILDREN.

    For additional information, refer to Material Safety Data Sheet.

    Top of Page

    LIMITED WARRANTY:


    RectorSeal® makes the Limited Express Warranty that when the instructions for storage and handling of our products are followed we warrant our products to be free from defects. THIS LIMITED EXPRESS WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND OF ANY OTHER OBLIGATION ON THE PART OF RECTORSEAL®. The sole remedy for breach of the Limited Express Warranty shall be the refund of the purchase price. All other liability is negated and disclaimed, and RectorSeal® shall not be liable for incidental or consequential damages.

    Top of Page

    MANUFACTURED IN U.S.A. BY

    RectorSeal®
    2601 Spenwick Drive • Houston, TX 77055 USA
    713-263-8001 • Fax 713-263-7577
    Toll-free 800-231-3345 • Fax 800-441-0051

    Back